DX³: advanced protection
Packed with innovative functions and technical features, the DX³ range meets the needs of the most demanding residential, commercial and industrial installations in terms of safety, performance and selectivity.
Comprising MCBs, RCBOs, RCCBs and add-on modules, the DX³ range ensures the safety of people and property as well as maximum continuity of service.
In = 1 to 125 A, 1P to 4P
Breaking capacity: 6000/10 kA; 10,000/16 kA; 25 kA, 36 kA, 50 kA – 230/400 V~
B, C and D curves
IEC 60898-1
As for the accompanying auxiliaries offer, it ensures accurate monitoring and control of any installation.
Versions compatible with prong-type or fork-type supply busbars.
DX³ 25 kA
Breaking capacity:. 25 kA – IEC 60947-2 – 400 V~. Can be equipped with DX³ signalling and remote tripping auxiliaries and motorised controls.
DX³ 6000
MCBs DX³ 6000 – 10 kA – thermal magnetic circuit breakers from 1 A to 63 A – B and C curves
Conform to IEC 60898-1. Compatible with both, prong-type and fork type supply busbars. Breaking capacity. 6000 – IEC 60898-1 – 400 V~. 10 kA – IEC 60947-2 – 400 V~. Can be equipped with DX³ signalling and remote tripping auxiliaries, motorised controls and add-on modules
MCBs DX³ 6000 – 10 kA – thermal magnetic MCBs from 0.5 A to 63 A – D curve
Conform to IEC 60898-1. Compatible with both prong-type and fork type supply busbars. Breaking capacity:. 6000 – IEC 60898-1 – 400 V~. 10 kA – IEC 60947-2 – 400 V~. Can be equipped with DX³ signalling and remote tripping auxiliaries, motorised controls and add-on modules
DX³ 10000
MCBs DX³ 10000 – 16 kA – thermal magnetic circuit breakers from 1 A to 125 A – B and C curves,1P to 4P.
Conform to IEC 60898-1. Compatible with prong-type and fork type supply busbars (except 80 A, 100 A and 125 A MCBs). Breaking capacity. 10000 – IEC 60898-1 – 400 V~. 16 kA – IEC 60947-2 – 400 V~. Can be equipped with DX³ signalling and remote tripping auxiliaries, motorised controls and add-on modules.
MCBs DX³ 10000 – 16 kA – thermal magnetic MCBs from 2 A to 125 A – D curve,1P to 4P.
Conform to IEC 60898-1. Compatible with both prong-type and fork type supply busbars (except 80 A, 100 A and 125 A MCBs). Breaking capacity:. 10000 – IEC 60898-1 – 400 V~. 16 kA – IEC 60947-2 – 400 V~. Can be equipped with DX³ signalling and remote tripping auxiliaries, motorised controls and add-on modules .
DX³ 36 kA
Breaking capacity:. 36 kA – IEC 60947-2 – 400 V~. Can be equipped with DX³ auxiliaries and accessories.
DX³ 50 kA
Breaking capacity:. 50 kA – IEC 60947-2 – 400 V~. Can be equipped with DX³ auxiliaries and accessories.
DX³ 16 kA
Operating voltage from 12 V= to 500 V=. Breaking capacity. 16 kA – IEC 60947-2 – 250 V=. 10 kA – IEC 60947-2 – 440 V=. 6 kA – IEC 60947-2 – 500 V=. Magnetic threshold from 5 to 7 In. Can be equipped with DX³ signalling and remote tripping auxiliaries and motorised controls.